Sign In | Join Free | My burrillandco.com
Home > Bimetal Temperature Switch >

KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector

Dongguan Linkun Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
     
    Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
    • Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
    • Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
    • Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
    • Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers
    • Buy cheap KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector from wholesalers

    KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector

    Ask Lasest Price
    Brand Name : LINKUN
    Model Number : KSD305 Thermostat
    Certification : UL ROHS CCC CUL VDE
    Price : Negotiation
    Payment Terms : L/C, D/A, D/P, T/T, Western Union
    Supply Ability : 100,000 pieces/month
    Delivery Time : 5-7 days
    • Product Details
    • Company Profile

    KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector

    KSD305 Bimetallic Thermostat Temperature Control Switch 40A Manual Reset Overheat Protector

    Product Performance and Principle

    The KSD305 temperature controller produced by our company is a single-pole single-throw temperature controller with a bimetallic temperature-sensing jump. The controller is divided into two types of automatic and manual reset by an insulating shell, a metal cover, a bimetal, a contact bridge, a spring, and an action rod, which constitute a unipolar normally closed switch. When the temperature change increases and reaches the preset deformation temperature of the bimetallic strip, the bimetallic strip operates to separate the contact bridge from the contact through the actuating rod, so that the switch that was originally in a normally closed state is disconnected. The cut-off temperature can be made according to the customer's needs. After the action, it needs to be manually reset to make it closed; automatic reset. When the temperature rises to the action temperature, the power is turned off and the temperature will drop. When it drops to the reset temperature, the temperature control will be closed. power ups.


    Product nameThermostat
    ModelKSD305
    Rated electrical performanceAC250V/50HZ,≤30A(Resistive load)
    Normal electric strengthAC50Hz1250V/1min No breakdown and flashover phenomenon
    Normal insulation resistance>300MΩ
    Contact formSPST (Single pole single throw)
    Normal closedThe temperature rises and the contacts open
    Life cycles6000 times
    Action temperature50℃-140℃
    Temperature tolerance+/-3℃,+/-5℃(According to customer needs)
    Temperature sensing materialBimetallic materials:TP140-80,B1,PA721,E3
    Connection methodFastening screw lock
    Contact materialCopper composite silver(T2+AgNi10)
    Insulation materialsPhenolic PF2A-151J(b)
    StructureBuilt-in
    Enclosure protection classIP00
    Insulation material PTI valuePTI175
    Heat and flame resistance classificationB type

    Notes


    Adopt contact temperature-sensing installation, so that the metal cover plane is close to the installation surface of the heating element during installation. Do not collapse and deform the cover surface during installation, so as not to affect performance.
    Do not allow liquid to penetrate into the thermostat during use, so as not to affect the electrical reliability and prevent leakage damage. This product is a single-pole connection method. When using it, it should be connected correctly according to the identification symbol. The rated current used cannot be greater than 30A.
    Products should be stored in a ventilated, clean, dry, and non-corrosive warehouse with a relative humidity of less than 90% and an ambient temperature of 40°C.


    Scope of Application


    It is suitable for electric water heaters, electric heating equipment, electric welding machines, steam generators and other high-power electrical appliances that require overheating protection.


    40A Thermal Overload Protector Phenolic Case 300MΩ Bimetal Thermostat Switch 0


    40A Thermal Overload Protector Phenolic Case 300MΩ Bimetal Thermostat Switch 1

    Wiring Diagram


    40A Thermal Overload Protector Phenolic Case 300MΩ Bimetal Thermostat Switch 2


    Temperature characteristics comparison table (see the table below):


    Action temperatureReset temperatureAction temperatureReset temperature
    20±5℃5±10℃125±5℃95±15℃
    30±5℃10±10℃130±5℃100±15℃
    45±5℃40±10℃135±5℃105±15℃
    50±5℃40±10℃140±5℃110±15℃
    55±5℃45±10℃145±5℃115±15℃
    60±5℃50±10℃150±5℃120±15℃
    65±5℃50±10℃155±5℃125±15℃
    70±5℃50±10℃160±5℃130±15℃
    75±5℃55±10℃165±5℃135±15℃
    80±5℃55±10℃170±5℃140±15℃
    85±5℃55±10℃175±5℃145±15℃
    90±5℃60±10℃180±5℃150±15℃
    95±5℃65±10℃185±5℃160±15℃
    100±5℃75±10℃190±5℃165±15℃
    105±5℃80±15℃200±5℃170±15℃
    110±5℃80±15℃210±5℃175±15℃
    115±5℃85±15℃215±5℃180±15℃
    120±5℃90±15℃220±5℃185±15℃

    The exterior shape and dimensions of the product